Sunday, July 28, 2013

RADIOFREQUENCY RADIATION LEAKAGE FROM MICROWAVE OVENS


 2013 Jul 16. [Epub ahead of print]

RADIOFREQUENCY RADIATION LEAKAGE FROM MICROWAVE OVENS.

Source

Center for Radiation Science and Technology, Al-Quds University, PO Box 20002, Jerusalem, Palestine.

Abstract

This work presents data on the amount of radiation leakage from 117 microwave ovens in domestic and restaurant use in the West Bank, Palestine. The study of leakage is based on the measurements of radiation emissions from the oven in real-life conditions by using a frequency selective field strength measuring system. The power density from individual ovens was measured at a distance of 1 m and at the height of centre of door screen. The tested ovens were of different types, models with operating powers between 1000 and 1600 W and ages ranging from 1 month to >20 y, including 16 ovens with unknown ages. The amount of radiation leakage at a distance of 1 m was found to vary from 0.43 to 16.4 μW cm-2 with an average value equalling 3.64 μW cm-2. Leakages from all tested microwave ovens except for seven ovens (∼6 % of the total) were below 10 μW cm-2. The highest radiation leakage from any tested oven was ∼16.4 μW cm-2, and found in two cases only. In no case did the leakage exceed the limit of 1 mW cm-2 recommended by the ICNIRP for 2.45-GHz radiofrequency. This study confirms a linear correlation between the amount of leakage and both oven age and operating power, with a stronger dependence of leakage on age.
PMID:
 
23861537
 
[PubMed - as supplied by publisher]

http://www.ncbi.nlm.nih.gov/pubmed/23861537

No comments: